Steel Tube Column Load Chart

The welded tube 4 is cooled and then driven through a series of sizing stations which qualifies the tube s final dimensions.
Steel tube column load chart. Astm 1085 table chart hss hollow structural section square structural tube. The safety factors use the numbers in the table below for strength. This specification covers cold formed welded carbon steel hollow structural sections hss for welded or bolted construction. Astm 1085 table chart hss hollow structural section square structural tube.
Beam loads support force calculator calculate beam load and supporting forces. At first this part of the site was intended for internal use only. Uniformly loaded beam overhanging post calculator. B to support a factored concentric load of 148 kips.
Enter the fy 46 ksi table page 9 for the 6 inch square erw hss. British universal columns and beams properties of british universal steel columns and beams. Square structural tube per. Simple beam point load at any location.
Hss manufacturing methods the transformation of steel strip into hollow structural sections hss is the result of operations including forming welding and sizing. This calculator will compute the acceptable allied galvanized steel tubing product size based on length and load criteria. Square tube assumes bending with one side parallel to the load think square vs diamond. When the tube is near its final shape and size.
He a steel beams properties of he a profiled. Two point loads at one third points on a simple beam. The largest effective length kl is 16 feet. The calculator can be utilized by anyone that knows the loading criteria of their application and whether the tube will be used as a beam or column.
Later we decided to open the tables for our visitors. Concrete columns estimate concrete volume required for concrete columns. Steel i beam. Rafter and ceiling joist forces.
You can find in our tables both dimensions and properties for majority of the standard steel section like steel beams and columns channels angles steel hollow sections. H height w width t wall thickness i area moment of inertia s elastic section modulus. H height w width t wall thickness i area moment of inertia s elastic section modulus. How to use the column load tables example 1 design the lightest 6 inch square erw hss column of f y 46 ksi astm a500 gr.
Loading in the middle of the longest tube is a worst case for stress on a cage member. Simple beam point load at midspan. And note the following. Rectangle structural tube per.
Read across the row at kl 16 ft. Vehicle load is a static distributed load in the middle of the longest tube and is 1 3 the tube length. Combined axial and bending load calculator. Common square rectangle tube sizes square rect 14ga 1 8 3 16 1 4 5 16 3 8 1 2 5 8 1x1 1 04 1 44 1 25x1 25 1x1 5 1 32 1 84 1 5x1 5 1x2 1 60 2 25 3 35 4 07 1 75x1 75 1 5x2 1x2 5 1 88 2 66 3 99 2x2 1 5x2 5 1x3 2 16 3 05 4 31 5 41 1 5x3 2 45 3 48 5 07 2 5x2 5 2 79 3 90 5 60 7 11.